{"title":"Safeco Fire Search - Suppression System","description":"\u003cp\u003eFire Search by Safeco Group is a self-contained, pneumatically-actuated automatic fire suppression system for enclosed electrical and electronic hazard areas — switchgear panels, MCC cabinets, server racks, and control cabinets. A linear thermal-detection tube acts as both fire detector and discharge conduit, releasing CO2 directly onto the fire with no external power, wiring, or control panel required.\u003c\/p\u003e","products":[{"product_id":"fire-search-saf-c-02-electrical-cabinet-fire-suppression-system-2kg-co2","title":"Fire Search SAF-C-02 Electrical Cabinet Fire Suppression System — 2kg CO2","description":"\u003ch3\u003eFire Search SAF-C-02 Electrical Cabinet Fire Suppression System — 2 kg CO₂\u003c\/h3\u003e\n\u003cp\u003eThe Fire Search SAF-C-02 is a compact, self-contained automatic fire suppression unit for small enclosed electrical and electronic hazard areas such as MCC cabinets, PLC\/SCADA cabinets, and control panels. It uses linear thermal-detection tubing that acts as both the detection element and the discharge conduit — when the tube bursts at the fire's hottest point, CO2 discharges directly onto the flame with no electrical actuation, external power, or control panel required.\u003c\/p\u003e\n\u003ch4\u003eKey Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No.:\u003c\/strong\u003e SAF-C-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgent fill:\u003c\/strong\u003e 2 kg CO₂\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorking pressure:\u003c\/strong\u003e 17 bar (optimal), 28 bar (maximum)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection tube length:\u003c\/strong\u003e 4 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem type:\u003c\/strong\u003e Direct low-pressure (DLP), pneumatically actuated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection tube:\u003c\/strong\u003e 6 mm OD \/ 4 mm ID modified Polyamide (PA), red\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTube burst temperature:\u003c\/strong\u003e ≥ 96°C at working pressure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurst pressure:\u003c\/strong\u003e 120 bar at ±20°C (without flame)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature (system):\u003c\/strong\u003e -20°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e 100 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCylinder material\/finish:\u003c\/strong\u003e Seamless steel, red polyester electrostatic paint\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection tube service life:\u003c\/strong\u003e 5-7 years under normal climatic conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 2 years from date of delivery (manufacturing defects)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Supply Includes\u003c\/h4\u003e\n\u003cp\u003ePre-charged pressure cylinder, DLP cylinder valve (pneumatic, brass nickel-plated), ball valve for service isolation, pressure gauge (0-27 bar, green\/red zone), red thermal-detection tube with quick-connector, end-of-line adapter with integrated gauge, safety clip, tamper seal, CrNi steel mounting bracket and clamps, factory nameplate. Optional low-pressure signal generator (LPSG) available for alarm integration.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFully self-contained — no external power required, even during mains failure\u003c\/li\u003e\n\u003cli\u003eNo control panel required, reducing cost and installation complexity\u003c\/li\u003e\n\u003cli\u003ePneumatic actuation eliminates dependence on electrical detection circuits or batteries\u003c\/li\u003e\n\u003cli\u003eFlexible tube routing reaches locations inaccessible to conventional point detectors\u003c\/li\u003e\n\u003cli\u003eMinimal false-discharge risk from a reliable thermal threshold\u003c\/li\u003e\n\u003cli\u003eTubing resistant to oils, hydraulic fluids, and many industrial solvents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTypical Applications\u003c\/h4\u003e\n\u003cp\u003eMedium\/low-voltage switchgear cabinets, motor control centres (MCC), server racks and UPS rooms, telecom equipment rooms, PLC\/SCADA control cabinets, data centre sub-floor zones, hydraulic power unit enclosures, compressor and pump control panels, generator control panels, transformer and rectifier cubicles.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e NFPA 12, NFPA 2001, EN 3-8 \/ PED 2014\/68\/EU, Egyptian Standard ES 6115\/2007, ISO 9001:2015, ISO 14001:2015, ISO 45001:2018.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCO2 Safety Notice:\u003c\/strong\u003e Carbon dioxide at suppression concentrations is lethal. Where installed in or adjacent to occupied spaces, warning signs, pre-discharge alarms, and personnel exclusion procedures are required per local civil defence regulations.\u003c\/p\u003e\n\u003cp\u003eSupplied by Safeco Group, Nasr City, Cairo, Egypt — Fire Protection Engineering.\u003c\/p\u003e","brand":"safeco group","offers":[{"title":"Default Title","offer_id":67178716233773,"sku":null,"price":0.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0762\/7820\/2413\/files\/forenginnering_Trading-7.png?v=1785340628"},{"product_id":"fire-search-saf-c-06-electrical-cabinet-fire-suppression-system-6kg-co2","title":"Fire Search SAF-C-06 Electrical Cabinet Fire Suppression System — 6kg CO2","description":"\u003ch3\u003eFire Search SAF-C-06 Electrical Cabinet Fire Suppression System — 6 kg CO₂\u003c\/h3\u003e\n\u003cp\u003eThe Fire Search SAF-C-06 is a self-contained automatic fire suppression unit sized for medium-scale enclosed electrical hazard areas such as switchgear panels, motor control centres, and server racks. Linear thermal-detection tubing acts as both the fire detector and the discharge conduit — when the tube bursts at the fire's hottest point, CO2 discharges directly onto the flame with no electrical actuation, external power, or control panel required.\u003c\/p\u003e\n\u003ch4\u003eKey Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No.:\u003c\/strong\u003e SAF-C-06\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgent fill:\u003c\/strong\u003e 6 kg CO₂\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorking pressure:\u003c\/strong\u003e 17 bar (optimal), 28 bar (maximum)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection tube length:\u003c\/strong\u003e 6 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem type:\u003c\/strong\u003e Direct low-pressure (DLP), pneumatically actuated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection tube:\u003c\/strong\u003e 6 mm OD \/ 4 mm ID modified Polyamide (PA), red\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTube burst temperature:\u003c\/strong\u003e ≥ 96°C at working pressure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurst pressure:\u003c\/strong\u003e 120 bar at ±20°C (without flame)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature (system):\u003c\/strong\u003e -20°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e 100 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCylinder material\/finish:\u003c\/strong\u003e Seamless steel, red polyester electrostatic paint\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection tube service life:\u003c\/strong\u003e 5-7 years under normal climatic conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 2 years from date of delivery (manufacturing defects)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Supply Includes\u003c\/h4\u003e\n\u003cp\u003ePre-charged pressure cylinder, DLP cylinder valve (pneumatic, brass nickel-plated), ball valve for service isolation, pressure gauge (0-27 bar, green\/red zone), red thermal-detection tube with quick-connector, end-of-line adapter with integrated gauge, safety clip, tamper seal, CrNi steel mounting bracket and clamps, factory nameplate. Optional low-pressure signal generator (LPSG) available for alarm integration.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFully self-contained — no external power required, even during mains failure\u003c\/li\u003e\n\u003cli\u003eNo control panel required, reducing cost and installation complexity\u003c\/li\u003e\n\u003cli\u003ePneumatic actuation eliminates dependence on electrical detection circuits or batteries\u003c\/li\u003e\n\u003cli\u003eFlexible tube routing reaches locations inaccessible to conventional point detectors\u003c\/li\u003e\n\u003cli\u003eMinimal false-discharge risk from a reliable thermal threshold\u003c\/li\u003e\n\u003cli\u003eTubing resistant to oils, hydraulic fluids, and many industrial solvents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTypical Applications\u003c\/h4\u003e\n\u003cp\u003eMedium\/low-voltage switchgear cabinets, motor control centres (MCC), server racks and UPS rooms, telecom equipment rooms, PLC\/SCADA control cabinets, data centre sub-floor zones, hydraulic power unit enclosures, compressor and pump control panels, generator control panels, transformer and rectifier cubicles.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e NFPA 12, NFPA 2001, EN 3-8 \/ PED 2014\/68\/EU, Egyptian Standard ES 6115\/2007, ISO 9001:2015, ISO 14001:2015, ISO 45001:2018.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCO2 Safety Notice:\u003c\/strong\u003e Carbon dioxide at suppression concentrations is lethal. Where installed in or adjacent to occupied spaces, warning signs, pre-discharge alarms, and personnel exclusion procedures are required per local civil defence regulations.\u003c\/p\u003e\n\u003cp\u003eSupplied by Safeco Group, Nasr City, Cairo, Egypt — Fire Protection Engineering.\u003c\/p\u003e","brand":"safeco group","offers":[{"title":"Default Title","offer_id":67178718986285,"sku":null,"price":0.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0762\/7820\/2413\/files\/EndSuction.png?v=1785340628"},{"product_id":"fire-search-saf-c-10-electrical-cabinet-fire-suppression-system-10kg-co2","title":"Fire Search SAF-C-10 Electrical Cabinet Fire Suppression System — 10kg CO2","description":"\u003ch3\u003eFire Search SAF-C-10 Electrical Cabinet Fire Suppression System — 10 kg CO₂\u003c\/h3\u003e\n\u003cp\u003eThe Fire Search SAF-C-10 is the largest cylinder in the Fire Search range, providing self-contained automatic fire suppression for larger enclosed electrical hazard areas including switchgear rooms, transformer\/rectifier cubicles, and generator control panels. Linear thermal-detection tubing acts as both the fire detector and the discharge conduit — when the tube bursts at the fire's hottest point, CO2 discharges directly onto the flame with no electrical actuation, external power, or control panel required.\u003c\/p\u003e\n\u003ch4\u003eKey Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart No.:\u003c\/strong\u003e SAF-C-10\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgent fill:\u003c\/strong\u003e 10 kg CO₂\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorking pressure:\u003c\/strong\u003e 17 bar (optimal), 28 bar (maximum)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection tube length:\u003c\/strong\u003e 10 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem type:\u003c\/strong\u003e Direct low-pressure (DLP), pneumatically actuated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection tube:\u003c\/strong\u003e 6 mm OD \/ 4 mm ID modified Polyamide (PA), red\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTube burst temperature:\u003c\/strong\u003e ≥ 96°C at working pressure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurst pressure:\u003c\/strong\u003e 120 bar at ±20°C (without flame)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature (system):\u003c\/strong\u003e -20°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e 100 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCylinder material\/finish:\u003c\/strong\u003e Seamless steel, red polyester electrostatic paint\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection tube service life:\u003c\/strong\u003e 5-7 years under normal climatic conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 2 years from date of delivery (manufacturing defects)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Supply Includes\u003c\/h4\u003e\n\u003cp\u003ePre-charged pressure cylinder, DLP cylinder valve (pneumatic, brass nickel-plated), ball valve for service isolation, pressure gauge (0-27 bar, green\/red zone), red thermal-detection tube with quick-connector, end-of-line adapter with integrated gauge, safety clip, tamper seal, CrNi steel mounting bracket and clamps, factory nameplate. Optional low-pressure signal generator (LPSG) available for alarm integration.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFully self-contained — no external power required, even during mains failure\u003c\/li\u003e\n\u003cli\u003eNo control panel required, reducing cost and installation complexity\u003c\/li\u003e\n\u003cli\u003ePneumatic actuation eliminates dependence on electrical detection circuits or batteries\u003c\/li\u003e\n\u003cli\u003eFlexible tube routing reaches locations inaccessible to conventional point detectors\u003c\/li\u003e\n\u003cli\u003eMinimal false-discharge risk from a reliable thermal threshold\u003c\/li\u003e\n\u003cli\u003eTubing resistant to oils, hydraulic fluids, and many industrial solvents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTypical Applications\u003c\/h4\u003e\n\u003cp\u003eMedium\/low-voltage switchgear cabinets, motor control centres (MCC), server racks and UPS rooms, telecom equipment rooms, PLC\/SCADA control cabinets, data centre sub-floor zones, hydraulic power unit enclosures, compressor and pump control panels, generator control panels, transformer and rectifier cubicles.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e NFPA 12, NFPA 2001, EN 3-8 \/ PED 2014\/68\/EU, Egyptian Standard ES 6115\/2007, ISO 9001:2015, ISO 14001:2015, ISO 45001:2018.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCO2 Safety Notice:\u003c\/strong\u003e Carbon dioxide at suppression concentrations is lethal. Where installed in or adjacent to occupied spaces, warning signs, pre-discharge alarms, and personnel exclusion procedures are required per local civil defence regulations.\u003c\/p\u003e\n\u003cp\u003eSupplied by Safeco Group, Nasr City, Cairo, Egypt — Fire Protection Engineering.\u003c\/p\u003e","brand":"safeco group","offers":[{"title":"Default Title","offer_id":67178719936557,"sku":null,"price":0.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0762\/7820\/2413\/files\/EndSuction.png?v=1785340628"},{"product_id":"safeco-fire-search-electrical-cabinet-suppression-system-co2","title":"Safeco CO2 Fire Search - Fire Suppression System","description":"\u003ch2\u003eSafeco Fire Search — Fire Suppression System (CO2)\u003c\/h2\u003e\n\u003cp\u003eSafeco Group's Fire Suppression System is a compact, self-contained automatic fire extinguishing unit designed to protect enclosed electrical and electronic hazard areas — switchgear panels, MCC cabinets, control rooms, server enclosures, and similar installations. A linear thermal-detection tube acts simultaneously as both the fire detection element and the extinguishing agent delivery conduit. Upon flame impingement or rapid heat rise, the tube softens and ruptures at the hottest point, immediately discharging extinguishing agent directly onto the fire source — with no electrical actuation, external power, or control panel required.\u003c\/p\u003e\n\u003ch3\u003eHow It Works\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eFire ignites inside the protected enclosure\u003c\/li\u003e\n\u003cli\u003eDetection tube ruptures at the hottest point\u003c\/li\u003e\n\u003cli\u003eInternal tube pressure drops; cylinder valve opens pneumatically\u003c\/li\u003e\n\u003cli\u003eExtinguishing agent discharges directly onto the fire through the burst aperture\u003c\/li\u003e\n\u003cli\u003eOptional low-pressure signal generator activates external alarm\/indication\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFully self-contained: no external power required, even during mains failure\u003c\/li\u003e\n\u003cli\u003eNo control panel required: reduces cost and installation complexity\u003c\/li\u003e\n\u003cli\u003ePneumatic actuation: no electrical detection circuits, solenoids, or batteries\u003c\/li\u003e\n\u003cli\u003eFlexible detection tube routing reaches areas inaccessible to point detectors\u003c\/li\u003e\n\u003cli\u003eFast response, especially in small enclosed volumes\u003c\/li\u003e\n\u003cli\u003eMinimal false-discharge risk\u003c\/li\u003e\n\u003cli\u003eSimple push-fit installation with pre-charged cylinder and wall bracket included\u003c\/li\u003e\n\u003cli\u003eOptional Low-Pressure Signal Generator (LPSG) for BMS\/fire alarm integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eExtinguishing Agent — CO2\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtinguishing mechanism\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOxygen dilution + cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOzone depletion potential\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZero\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrically conductive\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidue after discharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking cylinder pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17 bar (liquefied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCylinder color code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed with white data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for occupied spaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRequires evacuation (asphyxiation risk)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePost-discharge cabinet entry\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOnly after ventilation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003e⚠ CO2 Safety Notice: Carbon dioxide at suppression concentrations is lethal. When installed in or adjacent to normally-occupied spaces, appropriate safety measures — warning signs, pre-discharge alarms, and personnel exclusion procedures — must be implemented per local civil defence and safety regulations.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eCylinder Variants Available\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003cth\u003eAgent Fill\u003c\/th\u003e\n\u003cth\u003eWorking Pressure\u003c\/th\u003e\n\u003cth\u003eTube Length\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSAF-C-02\u003c\/td\u003e\n\u003ctd\u003e2 kg CO2\u003c\/td\u003e\n\u003ctd\u003e17 bar\u003c\/td\u003e\n\u003ctd\u003e4 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSAF-C-06\u003c\/td\u003e\n\u003ctd\u003e6 kg CO2\u003c\/td\u003e\n\u003ctd\u003e17 bar\u003c\/td\u003e\n\u003ctd\u003e6 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSAF-C-10\u003c\/td\u003e\n\u003ctd\u003e10 kg CO2\u003c\/td\u003e\n\u003ctd\u003e17 bar\u003c\/td\u003e\n\u003ctd\u003e10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDetection Tube Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModified Polyamide (PA), special thermal formulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4mm inner × 6mm outer diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptimal operating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−20°C to 65°C (long-term use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTube burst temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥96°C at working pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBurst pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 bar at ±20°C (without flame)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking pressure (optimal \/ max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17 bar \/ 28 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5–7 years under normal climatic conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMedium\/low-voltage switchgear cabinets\u003c\/li\u003e\n\u003cli\u003eMotor control centres (MCC)\u003c\/li\u003e\n\u003cli\u003eServer racks and UPS rooms\u003c\/li\u003e\n\u003cli\u003eTelecommunications equipment rooms\u003c\/li\u003e\n\u003cli\u003ePLC and SCADA control cabinets\u003c\/li\u003e\n\u003cli\u003eData centre sub-floor zones\u003c\/li\u003e\n\u003cli\u003eHydraulic power unit enclosures\u003c\/li\u003e\n\u003cli\u003eCompressor and pump control panels\u003c\/li\u003e\n\u003cli\u003eGenerator control panels\u003c\/li\u003e\n\u003cli\u003eTransformer and rectifier cubicles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplicable Standards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNFPA 12 — Standard on Carbon Dioxide Extinguishing Systems\u003c\/li\u003e\n\u003cli\u003eNFPA 2001 — Standard on Clean Agent Fire Extinguishing Systems\u003c\/li\u003e\n\u003cli\u003eEN 3-8 \/ PED 2014\/68\/EU — Pressure Equipment Directive\u003c\/li\u003e\n\u003cli\u003eEgyptian Standard ES 6115\/2007\u003c\/li\u003e\n\u003cli\u003eISO 9001:2015, ISO 14001:2015, ISO 45001:2018\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eWarranty: 2 years from date of delivery (manufacturing defects)\u003c\/em\u003e\u003c\/p\u003e","brand":"Safeco","offers":[{"title":"2KG","offer_id":67202774564909,"sku":null,"price":0.0,"currency_code":"EGP","in_stock":true},{"title":"6KG","offer_id":67202774597677,"sku":null,"price":0.0,"currency_code":"EGP","in_stock":true},{"title":"10KG","offer_id":67202774630445,"sku":null,"price":0.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0762\/7820\/2413\/files\/EndSuction.png?v=1785340628"}],"url":"https:\/\/safeco-group.com\/collections\/fire-search-suppression-system.oembed","provider":"safeco group","version":"1.0","type":"link"}