{"product_id":"safeco-fire-search-suppression-system-co2","title":"Safeco CO2 Fire Search - Fire Suppression System","description":"\u003ch2\u003eSafeco Fire Search — Fire Suppression System (CO2)\u003c\/h2\u003e\n\u003cp\u003eSafeco Group's Fire Suppression System is a compact, self-contained automatic fire extinguishing unit designed to protect enclosed electrical and electronic hazard areas — switchgear panels, MCC cabinets, control rooms, server enclosures, and similar installations. A linear thermal-detection tube acts simultaneously as both the fire detection element and the extinguishing agent delivery conduit. Upon flame impingement or rapid heat rise, the tube softens and ruptures at the hottest point, immediately discharging extinguishing agent directly onto the fire source — with no electrical actuation, external power, or control panel required.\u003c\/p\u003e\n\u003ch3\u003eHow It Works\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eFire ignites inside the protected enclosure\u003c\/li\u003e\n\u003cli\u003eDetection tube ruptures at the hottest point\u003c\/li\u003e\n\u003cli\u003eInternal tube pressure drops; cylinder valve opens pneumatically\u003c\/li\u003e\n\u003cli\u003eExtinguishing agent discharges directly onto the fire through the burst aperture\u003c\/li\u003e\n\u003cli\u003eOptional low-pressure signal generator activates external alarm\/indication\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFully self-contained: no external power required, even during mains failure\u003c\/li\u003e\n\u003cli\u003eNo control panel required: reduces cost and installation complexity\u003c\/li\u003e\n\u003cli\u003ePneumatic actuation: no electrical detection circuits, solenoids, or batteries\u003c\/li\u003e\n\u003cli\u003eFlexible detection tube routing reaches areas inaccessible to point detectors\u003c\/li\u003e\n\u003cli\u003eFast response, especially in small enclosed volumes\u003c\/li\u003e\n\u003cli\u003eMinimal false-discharge risk\u003c\/li\u003e\n\u003cli\u003eSimple push-fit installation with pre-charged cylinder and wall bracket included\u003c\/li\u003e\n\u003cli\u003eOptional Low-Pressure Signal Generator (LPSG) for BMS\/fire alarm integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eExtinguishing Agent — CO2\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtinguishing mechanism\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOxygen dilution + cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOzone depletion potential\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZero\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrically conductive\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidue after discharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking cylinder pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17 bar (liquefied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCylinder color code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed with white data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for occupied spaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRequires evacuation (asphyxiation risk)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePost-discharge cabinet entry\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOnly after ventilation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003e⚠ CO2 Safety Notice: Carbon dioxide at suppression concentrations is lethal. When installed in or adjacent to normally-occupied spaces, appropriate safety measures — warning signs, pre-discharge alarms, and personnel exclusion procedures — must be implemented per local civil defence and safety regulations.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eCylinder Variants Available\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003cth\u003eAgent Fill\u003c\/th\u003e\n\u003cth\u003eWorking Pressure\u003c\/th\u003e\n\u003cth\u003eTube Length\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSAF-C-02\u003c\/td\u003e\n\u003ctd\u003e2 kg CO2\u003c\/td\u003e\n\u003ctd\u003e17 bar\u003c\/td\u003e\n\u003ctd\u003e4 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSAF-C-06\u003c\/td\u003e\n\u003ctd\u003e6 kg CO2\u003c\/td\u003e\n\u003ctd\u003e17 bar\u003c\/td\u003e\n\u003ctd\u003e6 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSAF-C-10\u003c\/td\u003e\n\u003ctd\u003e10 kg CO2\u003c\/td\u003e\n\u003ctd\u003e17 bar\u003c\/td\u003e\n\u003ctd\u003e10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDetection Tube Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModified Polyamide (PA), special thermal formulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4mm inner × 6mm outer diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptimal operating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−20°C to 65°C (long-term use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTube burst temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥96°C at working pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBurst pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 bar at ±20°C (without flame)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking pressure (optimal \/ max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17 bar \/ 28 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5–7 years under normal climatic conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMedium\/low-voltage switchgear cabinets\u003c\/li\u003e\n\u003cli\u003eMotor control centres (MCC)\u003c\/li\u003e\n\u003cli\u003eServer racks and UPS rooms\u003c\/li\u003e\n\u003cli\u003eTelecommunications equipment rooms\u003c\/li\u003e\n\u003cli\u003ePLC and SCADA control cabinets\u003c\/li\u003e\n\u003cli\u003eData centre sub-floor zones\u003c\/li\u003e\n\u003cli\u003eHydraulic power unit enclosures\u003c\/li\u003e\n\u003cli\u003eCompressor and pump control panels\u003c\/li\u003e\n\u003cli\u003eGenerator control panels\u003c\/li\u003e\n\u003cli\u003eTransformer and rectifier cubicles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplicable Standards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNFPA 12 — Standard on Carbon Dioxide Extinguishing Systems\u003c\/li\u003e\n\u003cli\u003eNFPA 2001 — Standard on Clean Agent Fire Extinguishing Systems\u003c\/li\u003e\n\u003cli\u003eEN 3-8 \/ PED 2014\/68\/EU — Pressure Equipment Directive\u003c\/li\u003e\n\u003cli\u003eEgyptian Standard ES 6115\/2007\u003c\/li\u003e\n\u003cli\u003eISO 9001:2015, ISO 14001:2015, ISO 45001:2018\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eWarranty: 2 years from date of delivery (manufacturing defects)\u003c\/em\u003e\u003c\/p\u003e","brand":"Safeco","offers":[{"title":"2KG","offer_id":67202774564909,"sku":null,"price":0.0,"currency_code":"EGP","in_stock":true},{"title":"6KG","offer_id":67202774597677,"sku":null,"price":0.0,"currency_code":"EGP","in_stock":true},{"title":"10KG","offer_id":67202774630445,"sku":null,"price":0.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0762\/7820\/2413\/files\/EndSuction.png?v=1785340628","url":"https:\/\/safeco-group.com\/products\/safeco-fire-search-suppression-system-co2","provider":"safeco group","version":"1.0","type":"link"}