GST104A Conventional Fire Alarm Control Panel

The GST104A Conventional Fire Alarm Control Panel is designed in compliance with EN 54-2 1997 + A1: 2006 and EN 54-4 1997+A1: 2002+A2:2006 standards. It's compatible with GST conventional detectors, manual call points, and sounders. The panel is easy to install and operate — control functions are enabled by a key switch, and programming functions are enabled by a key switch and an internal switch.

Features & Benefits

  • 4 zones. Each zone can have a maximum of 32 conventional detectors; the total number of detectors and call points in a zone shall not exceed 32
  • Each zone can be programmed to work as fire alarm (default) or supervisory alarm mode
  • Each zone includes 2 indicators — a bi-color (red/green) indicator for fire/supervisory condition, and an amber fault/disable/test indicator
  • 1× Alarm output, settable as 24V or N/O, N/C
  • 3× sounder outputs — output 1 can be set as 24V or N/O, N/C; outputs 2 and 3 work as 24V only
  • 1× Disable/supervisory relay output (N/O, COM, N/C)
  • 1× Fault output (N/O, COM, N/C)
  • 1× Auxiliary power output: 450mA in standby, up to 1000mA in alarm mode
  • Reports short circuit and open circuit of detection zones, sounder outputs, and alarm output
  • Designed with standby batteries and space provision for two sealed lead-acid batteries
  • Easy operation to enable/disable zones, sounder outputs, and alarm output
  • Alarm Test function selectable with or without sounder notification
  • Output programmable for interlink between zones and sounder outputs, alert or evacuate tone, with or without delay
  • Different Silence/Reset/Test modes selectable to meet local requirements
  • Remote controls available for silence, evacuate, and reset
  • Three access levels settable via key control
  • Reserved repeater panel interface for fire alarm indication of multiple zones

Technical Specification

Primary Supply 220/230VAC +10%/-15%, 50/60Hz
Standby Power 7AH/24VDC
Maximum Internal Resistance of Batteries
Zone Quantity 4
Device Capacity 32 detectors per zone
End of Line for Zone AEOL (active end of line) or EOLR (0.5Watt/4.7kΩ)
End of Line for Others EOLR (0.5Watt/4.7kΩ) — sounder output, alarm output
Protection IP30
Standard EN54-2 1997 + A1: 2006, EN 54-4 1997+A1: 2002+A2:2006
Approval LPCB
Operating Environment 0°C ~ +40°C, ≤95% non-condensing
Dimensions 430mm(W) × 320mm(H) × 98mm(D)
Weight 4.2kg

Certificates & Compliance

  • Standards: EN 54-2 1997 + A1: 2006; EN 54-4 1997+A1: 2002+A2:2006
  • Certifications: LPCB

Compatible Devices

  • GST-RP16 Repeater Panel
  • DC-910xE Series Conventional Detectors
  • C-910x Series Conventional Detectors
  • DC-9204E Conventional Manual Call Point
  • C-940x Series Conventional Sounders and Strobes

Accessories & Tools

  • RB104A — Relay Board (Product No. 20101883)
  • P-9907 — Active End of Line (Product No. 10102406)
  • DP-9907 — Active End of Line (Product No. 10103044)

Part No.: GST104A · Product No.: 10105777

Shipping & Returns

Shipping
We deliver your parcel within 2–3 working days. As soon as your package has left our warehouse, you will receive a confirmation by email. This confirmation contains a tracking number that you can use to find out where your package is.

Returns
We offer free returns within 30 days. All you have to do is fill out the return slip that you received in your package and stick the prepaid label on the package.Please note that it can take 2 weeks for us to process your return. We will do our best to complete this process as soon as possible.

Shipping & Returns

Shipping
We deliver your parcel within 2–3 working days. As soon as your package has left our warehouse, you will receive a confirmation by email. This confirmation contains a tracking number that you can use to find out where your package is.

Returns
We offer free returns within 30 days. All you have to do is fill out the return slip that you received in your package and stick the prepaid label on the package.Please note that it can take 2 weeks for us to process your return. We will do our best to complete this process as soon as possible.

Warranty

We provide a 2-year limited warranty, from the date of purchase for all our products.

If you believe you have received a defective product, or are experiencing any problems with your product, please contact us.

This warranty strictly does not cover damages that arose from negligence, misuse, wear and tear, or not in accordance with product instructions (dropping the product, etc.).

Warranty

We provide a 2-year limited warranty, from the date of purchase for all our products.

If you believe you have received a defective product, or are experiencing any problems with your product, please contact us.

This warranty strictly does not cover damages that arose from negligence, misuse, wear and tear, or not in accordance with product instructions (dropping the product, etc.).

Secure Payment

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

We accept payments with :
Visa, MasterCard, American Express, Paypal, Diners Club, Discover and more.

Secure Payment

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

We accept payments with :
Visa, MasterCard, American Express, Paypal, Diners Club, Discover and more.

You may also like…

Related Products